28 Reference & Installation Manual
7.8 Restrict Arming on Wireless Supervision Trouble
Section [703]: Arming/Disarming Options
Option [7] OFF = Permit arming on wireless supervision failure (default)
Option [7] ON = Restrict arming on wireless supervision failure
If this option is enabled, the control panel will not arm the system if the control panel detects a wireless supervision trouble on one
or more zones. The control panel will not arm the system until all wireless supervision trouble conditions are rectified.
This feature will not function if the tamper recognition options (see Tamper Recognition on page 31) are disabled
or whenever the tampered zone is bypassed and the tamper bypass options (see Tamper Bypass Options on page
32) have been enabled.
7.9 Timed Auto-Arming
Section [741] = Partition 1, [742] = Partition 2
Option [1] OFF = Timed Auto-Arming Disabled (default)
Option [1] ON = Timed Auto-Arming Enabled
Each partition can be programmed to arm every day at the time specified by the Auto-arm Timer. The auto-arming options (see
Auto-Arming Options on page 29) determine the partition's arming method. Any open zones detected when a partition is auto-
armed will be bypassed regardless of their definition (except 24Hr zones). The control panel will enter a 60-second exit delay
period before arming the system. At this point, auto-arming can be cancelled by entering a valid access code. Once the partition
has successfully armed, the control panel can transmit the Timed Auto-arming report code programmed in section [860].
Example: To automatically arm partition 2 everyday at 6:15PM, enable Timed Auto-arming for partition 2 by turning on option [1]
in section [742]. Then key in 18:15 into section [762].
7.9.1 Auto-Arm Timer
Section [761] = Partition 1, [762] = Partition 2
Select the section corresponding to the desired partition and program the time (use the 24-hour clock i.e. 6:30PM =
18:30) that you wish the control panel to attempt to arm the selected partition and/or send the Late to Close report code.
7.10 No Movement Auto-Arming
Section [741] = Partition 1, [742] = Partition 2
Option [2] OFF = No Movement Auto-Arming Disabled (default)
Option [2] ON = No Movement Auto-Arming Enabled
If no movement occurs in a partition's protected area for the period specified by the No Movement Timer, the control panel can
automatically arm that partition. The Auto-arming Option determines the partition's arming method. Any open zones detected
when a partition is Auto-armed will be bypassed regardless of their definition (except 24Hr zones). Upon arming, the control panel
will transmit the No Movement report code if programmed in section [860]. Regardless of whether the system was successfully
armed or not, the control panel will always transmit the No Movement report code if programmed in section [860]. If No
Movement Auto-arming is disabled, the control panel will still send the No Movement report code at the time specified by the No
Movement Timer.
Example: To arm partition 1 whenever there is no movement for a period of 4 hours, enable No Movement Auto-arming for
partition 1 by turning on the [2] Option in section [741]. Then in section [749] enter 016 (16x15min = 240min = 4 hours).
7.10.1 No Movement Timer
Section [749] = Partition 1, [750] = Partition 2
000 to 255 x15min, Default = Disabled
Select the section corresponding to the desired partition and program the interval of time without movement you wish
the control panel to wait before arming and/or sending the No Movement report code. If No Movement Auto-arming is
disabled, the control panel can still send the No Movement report code when no movement has been detected for the
period specified by the No Movement Timer.