MG5000 21
6.3 Supervision Options
The Supervision Options cannot be used with any remote controls assigned to the control panel.
6.3.1 Supervision Bypass Options
Section [705]: Arming/Disarming Options
Option [8] ON = Generate Supervision Loss if detected on a Bypassed Wireless Transmitter Zone
(default)
Option [8] OFF = No Supervision Loss if detected on a Bypassed Wireless Transmitter Zone
When this feature is disabled, the Wireless Transmitter Supervision Options will follow the zone’s bypass definition.
This means the control panel will not perform any action if a Supervision Loss occurs on a bypassed zone. When this
feature is enabled, the Wireless Transmitter Options will ignore the bypass definition. This means the control panel will
generate an incident as per Wireless Transmitter Supervision Options if a supervision loss occurs on a bypassed zone.
6.3.2 RF Supervision Timer Settings
Section [706]: Supervision Options
Option [1] OFF = Check-in supervision interval is every 24 hours (default)
Option [1] ON = Check-in supervision interval is every 80 minutes
Option [1] defines the time period that the control panel will expect a check-in status signal from its assigned wireless
transmitters. For example, if the timer is set to 80 minutes (option [1] = ON), the control panel will expect a check-in
status signal to be sent from its assigned wireless transmitters within 80 minutes. If the Magellan MG5000 does not
receive a signal from one of its wireless transmitters within the period of time defined here, it can then generate a
trouble, an alarm, and/or can transmit a report code to the monitoring station (see Supervision Options on page 21).
6.4 RF Jamming Supervision
Section [700]: Zone Options
Option [5] OFF = RF Jamming Supervision Disabled
Option [5] ON = RF Jamming Supervision Enabled (default)
With option [5] ON, a trouble will be generated when the panel’s RF signal is jammed or encounters interference for a minimum of
10 seconds.
6.5 Wireless Serial Number Display
Section [960]: Find Wireless Serial Number Display
To see the wireless serial number display, enter section [960]. Press the anti-tamper switch of the desired module to be viewed.
The first digit of the serial number will illuminate on the keypad. Press [ENTER] to see each consecutive digit. Press [CLEAR] to
exit.
6.6 Remote Control Programming
The Magellan MG5000 accepts up to thirty-two fully programmable remote controls. Programming the remote controls is
accomplished in two steps:
1) Assign the remote controls to the Magellan MG5000 control panel.
2) Program the buttons on the remote controls.
6.6.1 Assigning a Remote Control to the Magellan MG5000
Sections [611] to [642]: Remote Controls 1 to 32 respectively
Remote controls are assigned to the panel using the Automatic Learning method via the MAster Quick Menu
Programming or by entering the serial number.
6.6.2 Deleting Assigned Remote Controls
Sections [611] to [642]: Remote Controls 1 to 32 respectively
Remote controls can be deleted by deleting the corresponding user (see the Quick Menu in the MG5000 User Guide).
How Do I Assign a Remote Control to the Magellan MG5000?
1) Press the [ENTER] key.
2) Enter your [
INSTALLER CODE] (default: 0000 / 000000) or [MAINTENANCE CODE] (default 1111/111111)
3) Enter the desired [
SECTION NUMBER] (from sections [651] to [682]).
4)
Enter the six-digit serial number of the remote
.
Vue de la page 24