Magellan v1.0 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Moniteurs à écran tactile Magellan v1.0. Magellan V1.0 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Model #: MG-6060

All-In-One Wireless Security System V1.0Model #: MG-6060Reference and Installation Manual

Page 2

8 Reference & Installation ManualHardwire Zone ConnectionsMagellan comes with two on-board hardwire zones. You can connect hardwire detection devi

Page 3 - Table of Contents

Paradox Magellan Systems 9X10 Transmitter ConnectionMagellan supports the X10 communication protocol. X10 is a communication protocol for remote con

Page 4

10 Reference & Installation ManualFigure 12: Mounting Magellan onto the Wall PlateFigure 13: Magellan’s Back PlateMounting Magellan on the WallMag

Page 5 - Introduction

Paradox Magellan Systems 11Programming MethodsWinLoad Installer Upload/Download SoftwareProgram the Magellan console remotely or on-site using the W

Page 6 - Quick Setup

12 Reference & Installation ManualUser CodesA person must be assigned to a user code in order to have access to Magellan. A user code defines the

Page 7 - 7.Time and Date

Paradox Magellan Systems 13Zone ProgrammingMagellan supports up to 16 wireless zones where each zone can be configured with a different zone definit

Page 8 - Installation

14 Reference & Installation ManualFollow/Stay ZonesSections [001] to [016]: Zones 1 to 16, 3-digit # = 004Follow/Stay zones function as follows:•

Page 9 - Programmable Outputs (PGMs)

Paradox Magellan Systems 1524Hr. Gas ZonesSections [001] to [016]: Zones 1 to 16, 3-digit # = 012When a 24Hr. Gas zone opens, whether it is armed or

Page 10 - Connection

16 Reference & Installation ManualIntellizone Delay TimerSection [065]: 010 to 255 seconds; Default = 48 secondsEnter the desired 3-digit value in

Page 11 - Location and Mounting

Paradox Magellan Systems 17Wireless ProgrammingThe Magellan system supports up to 16 wireless zones and two wireless doorbells. These wireless zones

Page 13 - Programming Methods

18 Reference & Installation ManualThe signal strength is displayed using two terms:• “Good”: This is an average reading and is acceptable.• “Weak”

Page 14 - User Codes

Paradox Magellan Systems 19Figure 20: Remote Control Button Options* = Hexa values A to F are keys [1] to [6] from Magellan’s Center Keypad.† = The

Page 15 - Zone Programming

20 Reference & Installation ManualArming and DisarmingRegular Arming Switches to Stay ArmingSection [092]: Option [4]Option [4] OFF = Switch to St

Page 16

Paradox Magellan Systems 21One-Touch ArmingSection [092]: Options [7] and [8]Option [7] OFF = One-touch Regular/Force arming disabledOption [7] ON =

Page 17 - Zone Options

22 Reference & Installation ManualAlarm OptionsBell Cut-off TimerSection [063]: 001 to 255 minutes; 000 = Disabled; Default = 4 minutesAfter an au

Page 18 - EOL (End-Of-Line) Zones

Paradox Magellan Systems 23presence and functionality. If a device has not sent a signal within the specified time period, Magellan can generate a t

Page 19 - Wireless Programming

24 Reference & Installation ManualReporting and Dialer SettingsReport CodesA report code is a 1- or 2-digit hexadecimal value consisting of digits

Page 20 - Assigning Remote Controls

Paradox Magellan Systems 25• Auxiliary Panic: Panic keys [4] and [6] (page 23) or the appropriate button(s) on a remote control (page 18) have been

Page 21

26 Reference & Installation ManualTable 8: Special Keys for Telephone NumbersCentral Station Telephone Numbers (CSTNs)Section [111] = Central Stat

Page 22 - Arming and Disarming

Paradox Magellan Systems 27[0] key followed by the 3-digit account number. Also, when using 3-digit account numbers, you must use 1-digit report cod

Page 23 - Paradox Magellan Systems 21

Paradox Magellan Systems 1Table of ContentsIntroduction... 3About Magellan and this Manual...

Page 24 - Alarm Options

28 Reference & Installation ManualDelay Between Dialing AttemptsSection [076]: 001 to 255 seconds; 000 = disabled; Default = 20 secondsThis delay

Page 25 - Panic Alarms

Paradox Magellan Systems 29Auto-Test ReportSection [071]: 001 to 255 days; 000 = Disabled; Default = Disabled Section [084]: Time (HH:MM)The Magel

Page 26 - Reporting and Dialer Settings

30 Reference & Installation ManualProgrammable OutputsA PGM is a programmable output that toggles to its opposite state (i.e. a normally open PGM

Page 27 - Console Telephone Numbers

Paradox Magellan Systems 31System SettingsSoftware ResetSection [201]Performing a software reset will reset all programmed sections back to the fact

Page 28 - Console Account Number

32 Reference & Installation ManualAC Failure Power failure detected. The system is running on the backup battery pack.Supervision Trouble Zone(s)

Page 29 - Event Call Direction

Paradox Magellan Systems 33WinLoad Software SettingsPanel Answer OptionsThe following two options define how Magellan answers an incoming call from

Page 30 - TLM Fail Timer

34 Reference & Installation ManualAppendix 1: Ademco Contact ID Report Code ListCID# Reporting Code Programming ValueMedical Alarms - 100100 Medic

Page 31 - Zone Restore Report Options

Paradox Magellan Systems 35CID# Reporting Code Programming Value335 Local printer paper out 54336 Local printer failure 55337 Expansion module DC lo

Page 32 - Programmable Outputs

36 Reference & Installation ManualCID# Reporting Code Programming Value525 Reversing relay disabled AE526 Notification appliance chk. #3 disabled

Page 33 - System Settings

Paradox Magellan Systems 37IndexNumerics001 to 016 ... 13–16021 to 036 ...

Page 34

2 Reference & Installation ManualPanel Answer Options ... 33Panel Identifier...

Page 35 - WinLoad Software Settings

38 Reference & Installation ManualAnswering machine override ...33Arming optionsAuto-arm options...

Page 36

Paradox Magellan Systems 39EEntry Delay 1 ...13Entry Delay 2 ...

Page 37

40 Reference & Installation ManualSpecial disarming...24System trouble...

Page 38

Paradox Magellan Systems 41VViewing ...17Viewing transmitter signal strength

Page 39 - Paradox Magellan Systems 37

42 Reference & Installation Manual

Page 40

Paradox Magellan Systems 43WARRANTYParadox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmansh

Page 43 - Paradox Magellan Systems 41

780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADATel.: (450) 491-7444 Fax: (450) 491-7313www.paradox.caPrinted in Canada - 09/2004 MAGELLAN

Page 44

Paradox Magellan Systems 3IntroductionAbout Magellan and this ManualMagellan is designed for fast and easy installation. Simply remove it from the bo

Page 45 - FCC WARNINGS

4 Reference & Installation ManualQuick SetupFollow these steps to quickly set up Magellan with the required settings for a basic security installa

Page 46

Paradox Magellan Systems 5When you are done the next menu option will appear. Press [NEXT] until you see the “Passwords” menu or press the [8] key t

Page 47

6 Reference & Installation ManualInstallationAC PowerMagellan requires a 9Vac (1A/9VA) or 16.5Vac (20VA) transformer (not included) to supply powe

Page 48

Paradox Magellan Systems 7For UL compliant installations, the Magellan console must be able to seize the telephone line and place a call in an emerg

Commentaires sur ces manuels

Pas de commentaire